BQLJD - LAPPING VEHICLES (A), DP-706
- MSDS: BQLJD
- Manufacturer: MAGER SCIENTIFIC INC
- Product Name: LAPPING VEHICLES (A), DP-706
- National Stock Number: 5350-00N035781
Product Identification
Product ID:LAPPING VEHICLES (A), DP-706
MSDS Date:02/25/1986
FSC:5350
NIIN:00N035781
MSDS Number: BQLJD
Responsible Party
DEXTER, MI 48130
US
Emergency Phone: 313-426-3885
Info Phone: 313-426-3885
Cage: 8R477
Contractor
Telephone: 313-426-3885
Cage: 8R477
Ingredients
ETHYLENE GLYCOL (SARA III)
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: 90-97%
OSHA PEL 50 PPM, C
ACGIH TLV: 50 PPM, C
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ETHANOL, 2-BUTOXY-; (BUTYL CELLUSOLVE)
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 2-10%
OSHA PEL S, 50 PPM
ACGIH TLV: S, 25 PPM; 9293
XYLENE (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 0.08%
OSHA PEL 100 PPM;150 STEL
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHANOL; (METHYL ALCOHOL) (SARA III)
CAS: 67-56-1
RTECS: PC1400000
Fraction By Weight: 2-10%
OSHA PEL S,200PPM/250STEL
ACGIH TLV: S,200PPM/250STEL; 93
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST: HEADACHE, NAUSEA, VOMITING.
INGEST: MAY CAUSE ABDOMINAL DISCOMFORT AND PAIN. DIZZINESS, LUMBAR
PAIN, OLIGURIA, UREMIA AND CNS DEPRESSION. KIDNEY DAMAGE MAY RESULT
FROM GROSS OVEREXPOSURE. SKIN : CONTACT MAY CAUSE IRRITATION.
ABSORPTION MAY CAUSE HEADACHE, NAUSEA, VOMITING. EYE: IRRITATION.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ANIMAL STUDIES HAVE CLEARLY
DEMONSTRATED DOSE-RELATED ADVERSE EFTS ON THE CNS, HEMATOPOIETIC
TISSUE, BLOOD, KIDNEYS, AND LIVER ASSOCIATED WITH THE
ADMINISTRATION OF ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE).
(EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO. 90-118).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. CONTACT A PHYSICIAN. INGEST: TWO
GLASSES OF WATER AND INDUCE VOMITING. CALL A PHYSICIAN. SKIN:
IMMEDIATELY FLUSH WITH PLENTY OW WATER. EYE: IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR AT LEAST 15 MIN. CALL A PHYSICIAN.
Fire Fighting
Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE WATER TO KEEP CONTAINERS COOL. WEAR
NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:WEAR APPROPRIATE EQUIPMENT AND CLOTHING.
REMOVE SOURCES OF IGNITION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. AVOID OPEN
FLAMES AND HIGH TEMPERATURE. USE ADEQUATE VENTILATION.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL: PREFERABLE. MECHANICAL (GENERAL): ACCEPTABLE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:EYE BATH AND SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:284F,140C
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTAMINATION WITH ALKALIES.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:THERMAL DECOMPOSITON MAY PRODUCE
CARBON MONOXIDE AND/OR CARBON DIOXIDE.
Disposal
Waste Disposal Methods:INCINERATE IN FURNACE. DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.